RIX Industries Flow Downs

Prime Coded Note:

R008

Revision:

2/4/2016

Description:

CORRELATION LIST OF CASTINGS/WELDS THAT REQUIRE RT/UT INSPECTION

Clause:

Coded Note Number: N3150
Revision: C004
Date: February 4, 2016
Title: CORRELATION LIST OF CASTINGS/WELDS THAT REQUIRE RT/UT INSPECTION

QUANTITY: THREE (3) COPIES
Correlation List - List shall identify all castings/welds that require radiographic/
ultrasonic inspection in assemblies (such as pumps, hoist and turbines) that have
multiple castings/welds, some of which are inaccessible after assembly.
Correlation List is to contain the following information as a minimum:
 What the part is in the assembly (Body, sleeve, coupling, bonnet etc.)
(include the applicable drawing and item numbers)
 Identify any RT and/or UT performed
 Traceability: Heat number, corresponding RT numbers to Heat and unit serial
numbers.
 Specific application: (castings, forgings, welds, etc.)

The following link contains assistance in meeting the requirements of this coded note.
http://supplier.huntingtoningalls.com/sourcing/doc_submittal_checklists.html