RIX Industries Flow Downs
Prime Coded Note:
Q070
Revision:
7/11/2017
Description:
Non-Destructive Test (NDT) Report - Unless otherwise specified, NDT shall be performed on 100% of the lot of products.Rev. 06/01/2020
Clause:
CERTIFICATE OF NDI/NDT Seller Shall include with each shipment a certificate for the NDI/NDT performed. As a minimum, the certification shall contain the following information: • Customer's Purchase Order/Contract number • Name and address of the Company performing NDI/NDT • Date of Inspection • Quantity of parts tested by part number Specification or other requirement defining the NDI/NDT acceptance/rejection criteria • Inspector/name/stamp • NDI/NDT certification level • NDI/NDT specification including revision • Material or item identification (part number, heat lot number, Foundry Record (FR) number • Material or item traceability (serial number, lot number, batch number, lot/date code) • Inspection results (accept/reject) • Reference to previous NDI/NDT reports for repair/rework if applicable • Reference to attached recordings i.e., films or photographs if applicable A record of the procedures or techniques used and actual results shall remain on file for at least five years after shipment to Customer and shall be furnished to Customer upon request. These records shall include all information listed above as well as acceptance/rejection criteria, and related test instrument data used in the NDI/NDT process.